Risk Assessment and Method Statement Template for Installation of under-floor power
This document should not be used until it has been thoroughly reviewed by a competent person.
| Company name: | |
| Project title: | |
| Location: | |
| Contract No: | |
| Author: | |
| Reviewed by: | |
| Date: | |
| Signature: |
This document has been provided as a template. By completing the section above, you take full responsibility for the use of this document.
Method Statement : Installation of under-floor power
Explanation
The installation of under-floor power involves the systematic placement and connection of power supply cables, encasements, and terminators or outlets beneath the flooring in both domestic and commercial settings. This process is typically undertaken as part of new build projects or refurbishment works, aiming to provide a discreet and efficient power distribution system that enhances the functionality and aesthetic appeal of the space. The task requires careful planning and execution to ensure that the power supply is safely and effectively integrated into the building’s infrastructure, meeting all relevant electrical standards and regulations.
Responsibilities
- Project Manager: Ensure all work is planned and executed according to the project timeline and safety regulations.
- Site Supervisor: Oversee daily operations, ensuring compliance with health and safety standards.
- Electrician: Install power supply cables, encasements, and outlets safely and according to electrical codes.
- Health and Safety Officer: Conduct risk assessments and ensure all safety measures are in place and followed.
- Labourer: Assist with the physical installation tasks, ensuring safe handling of materials and equipment.
- Quality Control Inspector: Verify that installations meet the required standards and specifications.
- Client Liaison: Communicate with clients to ensure their requirements are understood and met.
Equipment
- Insulated screwdrivers
- Cable cutters
- Wire strippers
- Voltage tester
- Power drill
- Tape measure
- Utility knife
- Fish tape
- Safety goggles
- Hard hat
- Gloves
- Knee pads
- Dust mask or respirator
- Torch or portable lighting
Operation
- Conduct a comprehensive risk assessment to identify potential hazards specific to the site.
- Ensure all personnel involved are trained and competent in electrical safety and installation procedures.
- Verify that all necessary permits and approvals have been obtained.
- Inspect and test all tools and equipment to ensure they are in safe working condition.
- Verify power isolation to prevent accidental energisation during installation.
- Inspect the work area to identify and address any potential hazards, such as uneven surfaces or obstructions.
- Gather all necessary tools and equipment, ensuring they are appropriate for the task.
- Lay out the power supply cables according to the design plan, ensuring they are free from kinks and not under tension.
- Securely install cable encasements, ensuring they are properly aligned and fixed to prevent movement or damage.
- Safely connect the cables to the terminators or outlets, following manufacturer instructions and ensuring all connections are secure and insulated.
- Conduct a thorough test of the installation to verify that all connections are correct and that there are no faults in the system.
- Replace and secure any floor panels that were removed during installation, ensuring they are level and stable.
- Perform a final inspection of the installation to ensure compliance with safety standards and rectify any issues identified.
- Restore the power supply and conduct a final test to confirm functionality.
- Record all relevant details of the installation process, including any issues encountered and how they were resolved, for future reference.
Risk Assessment : Installation of under-floor power
Electric Shock : Low (1)
Who might be harmed: Electricians | Installation Technicians | Construction Workers
Type of harm: Burns | Death | Electrocution
Initial Risk: Major (3) x Occasional (3) = Medium (9)
Controls
Residual Risk: Minor (1) x Improbable (1) = Low (1)
Who might be harmed:
Installation Workers | Other Tradespeople
Type of harm:
Back / Spinal Injury | Broken Bones | Cuts and Abrasions | Head Injury | Multiple / Various Injury
Initial Risk: Catastrophic (5) x Probable (4) = High (20)
Controls
Residual Risk: Minor (1) x Improbable (1) = Low (1)
Who might be harmed:
Electricians | Installation Technicians | Construction Workers
Type of harm:
Back / Spinal Injury | Muscular Injury
Initial Risk: Major (3) x Occasional (3) = Medium (9)
Controls
Residual Risk: Minor (1) x Improbable (1) = Low (1)
Who might be harmed:
Installation Workers | Other Construction Personnel
Type of harm:
Asbestosis / Lung Cancer / Mesothelioma | Respiratory damage / Asthma / COPD | Eye Damage
Initial Risk: Catastrophic (5) x Probable (4) = High (20)
Controls
Residual Risk: Minor (1) x Improbable (1) = Low (1)
Who might be harmed:
Installation Workers | Other Construction Personnel | Building Occupants
Type of harm:
Burns | Death | Smoke Inhalation
Initial Risk: Severe (4) x Probable (4) = Medium (16)
Controls
Residual Risk: Minor (1) x Improbable (1) = Low (1)
Who might be harmed:
Installation Technicians | Electricians | Maintenance Workers
Type of harm:
Asphyxia | Crush / Entrapment | Death | Respiratory damage / Asthma / COPD | Smoke Inhalation
Initial Risk: Major (3) x Frequent (5) = Medium (15)
Controls
Residual Risk: Minor (1) x Improbable (1) = Low (1)
Who might be harmed:
Installation Workers | Maintenance Personnel
Type of harm:
Asbestosis / Lung Cancer / Mesothelioma | Dermatitis | Respiratory damage / Asthma / COPD
Initial Risk: Severe (4) x Occasional (3) = Medium (12)
Controls
Residual Risk: Minor (1) x Improbable (1) = Low (1)
Who might be harmed:
Installation workers | Site supervisors | Other tradespeople on site | Maintenance personnel
Type of harm:
Asbestosis / Lung Cancer / Mesothelioma | Respiratory damage / Asthma / COPD | Death
Initial Risk: Catastrophic (5) x Probable (4) = High (20)
Controls
Residual Risk: Minor (1) x Improbable (1) = Low (1)
Who might be harmed:
Installation workers | Site supervisors | Other tradespeople on site
Type of harm:
Asbestosis / Lung Cancer / Mesothelioma | Respiratory damage / Asthma / COPD
Initial Risk: Major (3) x Frequent (5) = Medium (15)
Controls
Residual Risk: Minor (1) x Improbable (1) = Low (1)
Who might be harmed:
Installation workers | Site supervisors | Other tradespeople on site
Type of harm:
Asbestosis / Lung Cancer / Mesothelioma | Asphyxia | Death | Illness | Respiratory damage / Asthma / COPD | Smoke Inhalation
Initial Risk: Catastrophic (5) x Probable (4) = High (20)
Controls
Residual Risk: Minor (1) x Improbable (1) = Low (1)
Who might be harmed:
Installation workers handling materials.
Type of harm:
Illness | Death
Initial Risk: Catastrophic (5) x Probable (4) = High (20)
Controls
Residual Risk: Minor (1) x Improbable (1) = Low (1)
Who might be harmed:
Electricians | Construction workers | Maintenance personnel
Type of harm:
Eye Damage
Initial Risk: Major (3) x Occasional (3) = Medium (9)
Controls
Residual Risk: Minor (1) x Improbable (1) = Low (1)
Who might be harmed:
Installation workers handling lead-contaminated materials.
Type of harm:
Dermatitis
Initial Risk: Catastrophic (5) x Occasional (3) = Medium (15)
Controls
Residual Risk: Minor (1) x Improbable (1) = Low (1)
The installation of under-floor power involves the systematic placement and connection of power supply cables, encasements, and terminators or outlets beneath the flooring in both domestic and commercial settings. This process is typically undertaken as part of new build projects or refurbishment works, aiming to provide a discreet and efficient power distribution system that enhances the functionality and aesthetic appeal of the space. The task requires careful planning and execution to ensure that the power supply is safely and effectively integrated into the building’s infrastructure, meeting all relevant electrical standards and regulations. The installation of under-floor power presents several hazards that must be carefully managed to ensure the safety of all personnel involved. The risk of electric shock is significant, particularly when working with live electrical components, necessitating strict adherence to lockout/tagout procedures. Tripping hazards are prevalent due to cables and equipment being placed on the floor, requiring vigilant housekeeping practises. Musculoskeletal injuries may occur from lifting heavy equipment and maintaining awkward postures, such as bending or kneeling for extended periods. Dust and debris generated during installation can pose respiratory hazards, necessitating appropriate personal protective equipment. Fire hazards are a concern due to potential electrical faults or improper installation, underscoring the importance of compliance with electrical safety standards. Working in confined spaces under the floor can present additional risks, including limited access and ventilation. Furthermore, in older buildings, there may be exposure to hazardous substances such as asbestos, requiring thorough risk assessments and control measures. This document has been provided as a template. By completing the section above, you take full responsibility for the use of this document.
Tripping Hazards : Low (1)
Musculoskeletal Injuries : Low (1)
Dust and Debris : Low (1)
Fire Hazards : Low (1)
Confined Spaces : Low (1)
Hazardous Substances : Low (1)
COSHH Assessment : Installation of under-floor power
Asbestos
Asbestos was historically used for its fire-resistant and insulating properties in construction materials such as insulation, floor tiles, and roofing.
Inhalation : Low (1)
Silica dust
Silica dust is not intended for use; rather, it is a hazardous byproduct generated during activities such as cutting, grinding, or drilling concrete, masonry, or other silica-containing materials.
Inhalation : Low (1)
Lead dust
Lead dust may be encountered during refurbishment projects, particularly when disturbing old paint or materials that contain lead.
Inhalation : Low (1)
Ingestion : Low (1)
Eye Contact : Low (1)
Skin Contact : Low (1)
Toolbox Talk : Installation of under-floor power
Introduction
Hazards
Installation of under-floor power : Rules
Installation of under-floor power : Warnings
Induction Record
Company name:
Project title:
Location:
Contract No:
Subject:
Risk Assessment and Method Statement : Installation of under-floor power
Tutor:
Date:
Signature:
Name Comments Signature Date